| Power | 100 to 240 VAC, 50/60 Hz, 6.5A (Max.) |
| Frequency | 1 to 100 bpm (f) |
| Battery | 120 minutes |
| Tidal Volume | 20 to 1500 mL (VT) |
| PEEP | Integrated electronic PEEP OFF, 4~30cm H2O |
| Flow Trigger | 1 to 15 L/min (F) |
| Peak Flow | Greater Than 120 L/min |
| Pressure Control | 5 to 70cm H2O |
| Pressure Support | 5 to 60cm H2O |
| Pressure Limit | (PEEP+5) to 70cm H2O |
| Vaporiser Mounting | 2 positions, selectatec mounting system, optional 3rd parking position |
| Gas Supply | Pipeline O2, N2O, Air Cylinder O2, N2O (Optional) |
| Pressure Gauge | Pipeline pressure gauges and Cylinder pressure gauges |
| Flow Meter | Choice of Electronic Flow meter or traditional rotameters |
| ACGO connector | 22 / 15mm |
| APL Valve | 2 to 70cm H2O |
| By Pass | Automatic change soda lime during operation |
| Bag and Vent switch | Switch for manual ventilation and mechanical ventilation |
| Physical Dimension | 1570 x 880 x 1000mm3 (H x W x D) |
| IE Ratio | 41 to 110 (increment 0.5) |
| Storage | 2 spacious drawers |
| Net weight | 108 kg |
| Communication Connector | VGA, RS232, RJ45, debugging interface |
| Inspiratory time | 0.1 to 10s (increment 0.1 s) |
| Inspiratory Pause | OFF, 5% to 50% (TipTi) |
Neptune Prime Anaesthesia Workstation
Model No.:
Neptune PRIME are advanced anesthesia workstations that combine efficient patient care with a simplicity of operation. The modular workstation among its host of features provides a choice between integrated electronic flowmeter and the traditional rotameters. Its advanced ventilation and monitoring capabilities provide a controlled and precise workflow during all stages of anesthesia delivery making it suitable for all ages of patients from neonates to adults. The ergonomically designed workstations provide a clean and uncluttered work environment by completely integrating the ventilator, breathing system, vaporizer, suction, and scavenging system.
Features:
- Fully integrated, compact & ergonomic design
- Digital Hypoxic Device
- Fail-proof audio/visual oxygen failure alarm
- An automatic cut-off of N2O in case of O2 failure
- Dual/ Triple mounting of vaporizers
- Parking block for the third vaporizer (optional)
- Auxiliary O2 flowmeter
- Plug-In upgrade modules
- Dual flow sensing capability at inhalation and exhalation ports
- Backup O2 control independent of the electrical failure
- Set and user-defined priority alarms
- ACGO allows use with semi-open circuits
- Top light and backlight illumination
- Trolley mounted with lockable castors
- O2 flush 35-75 l/min
- Air/N2O interlock switch
Most Effective And Efficient Patient Care:
- Active Gas Scavenging System(Optional)
- Auxiliary-Flowmeter
- O2 Auxiliary Flowmeter
- 15.6” Display Screen
- Plug-In Upgrade Modules
Circle Absorber Breathing System:
- Fully autoclavable at 134 C and latex free
- Automatic absorber heating technology to avoid water condensation
- Automatic absorber By-pass to change soda lime during surgery
- Single canister system
- Integrated bag/vent switch for an automatic changeover from manual to mechanical ventilation
- Integrated pressure manometer, calibrated APL valve, O2 sensor port